Provides fully automated collection, location, and identification, and supports operator manual intervention and in-mission processing modifications and adjustments (in both manned and unmanned operations) |
|

|
Reports frequency, pulse width, time of pulse intercept, direction of arrival (monopulse), amplitude, and pulse repetition interval (PRI), along with other parameters. Correlates and updates reports and databases and provides emitter location. Automated or manual reporting capabilities in standard government formats. |
|

|
Couples wideband collection and processing with azimuth and elevation (AZ/EL) antenna arrays to provide rapid threat/emitter location and high probability of intercept (POI). 320 or 640 MHz instantaneous frequency processing with six selectable channelized bandwidths (80, 40, 20, 10, 5, and 2 MHz). |
| |
 |
Compatible with manned (operator on platform) or unmanned operation |
| |
 |
Supports GPS sync for high accuracy of time of intercept (TOI) and cooperative multi-platform targeting |
| |
 |
Processes, identifies, and locates modern threat types and modulations |
| |
 |
Supports automated and manual generation of reports |
| |
 |
Records pulse-level pulse descriptor word (PDW) data for post-mission analysis, mission preparation/refinement, and operator training through entire mission playback |
| |
 |
Provides manual analysis modes for operator/analyst confirmations and augmentation |
| |
 |
Provides full system built-in test and diagnostic analysis tools that support two- or three-level maintenance concepts |
| |
 |
Has low size, weight, and power: <2.5 cuft., ≈100 lb, <500W |
| |
 |
Is designed for MIL airborne, surface, and ground environments – MIL-STD-810 and MIL-STD-461 compatibility and environmental design |
| |
 |
Supports a flexible architecture that allows ease of installation on various platforms and ability to tailor systems for mission and customer requirements |
| |
|

|
Growth slots for secondary antenna/tuner thread |
| |
 |
Designed for low recurring cost and cost of ownership through modularity and ease of maintenance |
| |
 |
Requires no on-platform calibration (in most installations) |
| |
 |
Includes full logistics support and training |